Page 9

MODEL 6700 Downflow

Control Operation (Cont’d.)

Control Operation During Programming

The control will only enter the Program Mode with the valve in Service and operating on line power. While in the
Program Mode the control will continue to operate normally monitoring water usage and keeping all displays up to date.
Control programming is stored in memory permanently with or without line or battery backup power.

Lockout Input Operation

The Lockout Arrow will turn on whenever a Lockout Signal is being received by the control. Any requests for
regeneration will be delayed until this signal is removed. Regeneration will then proceed normally.

Keypad Operation

Extra Cycle Button

Pushing this button will initiate a regeneration cycle independently of actual valve conditions.

1.

With immediate regeneration valves this extra regeneration would occur immediately.

2.

With delayed regeneration valves this extra regeneration would occur at the set Regeneration Time. A regeneration
cycle can be forced to occur immediately by pushing and holding in this button for 5 seconds.

Program Button

This button is used by the installer to program those settings indicated on the front panel by red LEDs.

Up Set Button

This button is used to set the current time of day, adjust time remaining in a regeneration cycle step, and in valve
programming. The Up Arrow Button will increment a display setting.

Down Set Button

This button is used to set the current time of day, adjust time remaining in a regeneration cycle step, and in valve
programming. The Down Arrow Button will decrement a display setting.

Low Battery Indicator

When the control is operating on line power this red LED will turn on whenever the

9V Alkaline Battery (Not Included)

used for memory backup needs to be replaced. The battery is stored inside the top cover. In the event of a power
outage, the battery will maintain current operating data for approximately 24 hours at maximum battery capacity.