Introduction – Cobalt Digital COMPASS 9284 3G_HD_SD-SDI 8X4 Video Routing Switch User Manual
Page 25

9284-OM (V1.3)
9284 PRODUCT MANUAL
1-21
Introduction
9284 Functional Description
“T”: Trigger a Salvo Connect Sequence
The command “T” is used to trigger a previously set up salvo (set using the
“P” command above). It must be followed by a register letter from A to Z or a
register number from 1 to 256 giving the register to be triggered.
For example, the command:
** TB D180 TC !!
says to trigger salvo register B (same as 2), delay 180 sync intervals, then
trigger salvo register C (same as 3). When the register is triggered, this means
that the connect commands stored in it take effect.
If a salvo is triggered and it attempts to connect a locked output or port, or a
disallowed input/output pair, or a port to itself, the salvo trigger operation is
aborted, no crosspoint changes are performed, and an error is reported:
“ERROR Salvo Has Locked Xpts”.
From Syntax
Description
Host
T reg
Trigger a list of connect commands
stored in a salvo register.
Router
(None)