9071 Processing Error Troubleshooting

Table 3-4 provides 9071 processing troubleshooting information. If the 9071
card exhibits any of the symptoms listed in Table 3-4, follow the
troubleshooting instructions provided.

In the majority of cases, most errors are caused by simple errors where the
9071 is not appropriately set for the type of signal being received by the card.

Note:

The error indications shown below are typical for the corresponding error con-
ditions listed. Other error indications not specified here may also be displayed
on DashBoard™ and/or the 9071 card edge status indicators.

Note:

Where errors are displayed on both the 9071 card and network remote con-
trols, the respective indicators and displays are individually described in this
section.

Card seating within slots

Make certain all cards are properly seated within its frame slot. (It is best to assure
proper seating by ejecting the card and reseating it again.)

Check status indicators and
displays

On both DashBoard™ and the 9071 card edge indicators, red indications signify an
error condition. If a status indicator signifies an error, proceed to the following tables in
this section for further action.

Troubleshoot by substitution

All cards within the frame can be hot-swapped, replacing a suspect card or module
with a known-good item.

Table 3-3

Basic Troubleshooting Checks — continued

Item

Checks

Table 3-4

Troubleshooting Processing Errors by Symptom

Symptom

Error/Condition

Corrective Action

DashBoard™ shows Video

yellow icon and Input Invalid
message in 9071 Card Info
pane.

• Card edge Input Format LEDs

show continuous cycling.

No video input present

Make certain intended video source is
connected to appropriate 9071 card video input.
Make certain BNC cable connections between
frame Rear I/O Module for the card and signal
source are OK.

Ancillary data (closed captioning,
timecode, Dolby

®

metadata,

AFD) not transferred through
9071.

• Control(s) not enabled

• Make certain respective control is set to On or

Enabled (as appropriate).

• VANC line number conflict

between two or more
ancillary data items

• Make certain each ancillary data item to be

passed is assigned a unique line number (see
Ancillary Data Line Number Locations and
Ranges
on page 3-6).