9400-series function submenu list and descriptions – Cobalt Digital COMPASS 9414 4 In _ 4 Out Fiber-to-BNC Receiver _ Crosspoint Card User Manual
Page 32

3
9400-Series Function Submenu List and Descriptions
3-6
9400-SERIES PRODUCT MANUAL
9400S-OM (V1.1)
(continued)
• Channel Disable Alarm Select
When checked, disables any alarms for the selected output channel.
Disabling unused channels circumvents nuisance alarm propagation for
unused output channels.
Note: On cards with less than four fiber output channels, DashBoard may
still have DIS. ALARM controls for the unpopulated channels. Make
certain these are set to disabled (checked) to prevent nuisance
alarms for unpopulated channels.
• Driver Module Temperature Alarm
Threshold Select
Allows custom settings of global temperature alarm (caution state: yellow
alert propagated) or warning (warning state: red alert propagated).
CAUTION
Alarm thresholds should not be set at values that exceed pre-defined
threshold for FOM (fiber optic module) fitted to the card. This information
can be found using the Fiber Optics Module information/status tab.
Refer to Fiber Optics Module tab on next page for more information.
Table 3-1
9401-9404 (Tx) Card Function Submenu List — continued
•
•
•