Setup – TC Electronic LM2 Plug-in User Manual
Page 16

16 /
LM6 Radar Loudness Meter
Setup
Momentary Range
EBU +9 or EBU +18
Set range on the radar-meter
EBU mode meters are able to display to show two different momentary displays: One
with a narrow loudness range intended for normal broadcast and denoted “EBU +9”,
and one with a wide loudness range intended for film, drama and wide range music
denoted “EBU +18”.
The “EBU +9” setting gives a momentary meter range from -18 to +9 LU, while the
“EBU +18” settings gives a momentary range from -36 to 18 LU.
Radar Speed
Radar Speed controls how long time each radar revolution takes. Select from 1
minute to 24 hours. You may “zoom” between the settings, as long as the history isn’t
reset. Pressing the Reset key resets the meter and descriptor history.
Radar Resolution
Radar Resolution sets the difference in loudness between each concentric circle in
the Radar between 3 and 12 dB. Choose low numbers when targeting a platform with
a low dynamic range tolerance. You may “zoom” between the settings, as long as the
history isn’t reset.