MAX6657/MAX6658/MAX6659

_______________________________________________________________________________________

5

PIN

MAX6657
MAX6658

MAX6659

NAME

FUNCTION

1

1

V

CC

Supply Voltage Input, +3V to +5.5V. Bypass to GND with a 0.1µF capacitor. A 200

Ω

series resistor is recommended but not required for additional noise filtering. See
Typical Operating Circuit.

2

3

DXP

Combined Remote-Diode Current Source and A/D Positive Input for Remote-Diode
Channel. DO NOT LEAVE DXP FLOATING; connect DXP to DXN if no remote diode
is used. Place a 2200pF capacitor between DXP and DXN for noise filtering.

3

4

DXN

Combined Remote-Diode Current Sink and A/D Negative Input. DXN is internally
biased to one diode drop above ground.

4

6

OVERT1

Overtemperature Active-Low Output, Open-Drain. Output is logic low only when
temperature is above the software programmed threshold.

5

7, 8

GND

Ground

6

9

ALERT

SMBus Alert (Interrupt) Active-Low Output, Open-Drain. Asserts when temperature
exceeds user-set limits (high or low temperature). Stays asserted until acknowledged
by either reading the Status register or by successfully responding to an Alert
Response address. See

ALERT

Interrupts.

7

12

SMBDATA

SMBus Serial-Data Input/Output, Open-Drain

8

14

SMBCLK

SMBus Serial-Clock Input

—

5

ADD

SMBus Address-Select Pin. The MAX6659 is set to one of three available addresses
(connect to V

CC

, GND, or leave open). See Slave Addresses section.

—

10

OVERT2

Overtemperature Active-Low Output, Open-Drain. Output is logic low only when
temperature is above the software programmed threshold.

—

15

STBY

Hardware Standby Input. Temperature and comparison threshold data are retained in
standby mode. If

STBY is low, the IC is put into standby mode.

—

2, 11, 13, 16

N.C.

Not internally connected. Do not make connections to these pins.