Stereo Audio Taper Potentiometers
with Pushbutton Interface

10

______________________________________________________________________________________

Click/Pop Suppression

The click/pop suppression feature reduces the audible
noise (clicks and pops) that result from wiper transitions.
The MAX5456/MAX5457 minimize this noise by allowing
the wiper position changes only when V

H_

= V

L_

. Thus,

the wiper changes position only when the voltage at L_ is
the same as the voltage at the corresponding H_. Each
wiper has its own suppression and timeout circuitry (see
Figure 5a). The MAX5456/MAX5457 change wiper posi-
tion after 32ms or when V

H_

= V

L

, whichever occurs first

(see Figure 5b).

The suppression circuitry monitors left and right chan-
nels separately. In volume-control mode, when the first
wiper changes position, the second wiper has 32ms to
change or it will be forced to change.

Power-On Reset

The power-on comparators monitor V

DD

- V

SS

and

V

LOGIC

- GND. A power-on reset is initiated when either

of the supplies is brought back to normal operating
voltage. The power-on-reset feature sets both wipers to
-12dB. Power-on reset places the MAX5457 in volume-
control mode.

DN OR UP

1

0

USER PRESSES PUSHBUTTON

SWITCH

CONTACT

IS BOUNCING

SWITCH

CONTACT

IS STABLE

SWITCH

CONTACT

IS BOUNCING

READY TO ACCEPT
ANOTHER KEYPRESS

INPUT ACCEPTED

t

IPW

t

WS

t

HPW

DEBOUNCE BY

WAITING FOR

STABLE LOW, t

IPW

WAIT FOR

FIRST ZERO

CROSSING, t

WS

DEBOUNCE BY

WAITING FOR

STABLE HIGH, t

HPW

V

H

V

L

WIPER MOTION

WIPER MOVES HERE

2dB
STEPS

Figure 5a. Wiper Transition Timing Diagram

Advertising