Typical Applications
(Continued)
Sampling an AC Input Signal
Note 1
Oversample whenever possible keep fs
l
2f(
b
60) to eliminate input frequency folding
(aliasing) and to allow for the skirt response of the filter
Note 2
Consider the amplitude errors which are introduced within the passband of the filter
70% Power Savings by Clock Gating
(Complete shutdown takes
30 seconds )
Power Savings by A D and V
REF
Shutdown
TL H 5671 – 11
Use ADC0801 02 03 or 05 for lowest power consumption
Note Logic inputs can be driven to V
CC
with A D supply at zero volts
Buffer prevents data bus from overdriving output of A D when in shutdown mode