Rainbow Electronics GM862-GPS User Manual
Page 77

Easy Script
in Python
80000ST10020a Rev.8 - 01/10/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 77 of 100
• Run a terminal emulator application (e.g. Hyper Terminal) to trace the activity of the Python
script, with the following setting:
connected
COM
virtual port #4 set in Telit
CMUX window (COM10 in
the figure)
Bit rate
115 200
Data bits
8
Parity
No parity
Stop bit
1
Flow control
Hardware
In the Telit Serial Port Mux window, “Status:” of the Virtual Port#4, after establishing
connection in Hyper Terminal, will change from Idle to Opened
• Power on the module and wait for at least 10 seconds without sending any AT command
(except AT<Enter>);
In the Telit Serial Port Mux window, “Status:” of the Modem Port: will change in the
following way (before 10 seconds expired):
Idle Æ cycle between Connecting and Error Æ Connected