Pin description – Rainbow Electronics MAX6696 User Manual

Page 5

Advertising
background image

MAX6695/MAX6696

Dual Remote/Local Temperature Sensors with

SMBus Serial Interface

_______________________________________________________________________________________

5

Pin Description

PIN

MAX6695

MAX6696

NAME

FUNCTION

1

2

V

CC

Supply Voltage Input, +3V to +3.6V. Bypass to GND with a 0.1µF capacitor. A
47

Ω series resistor is recommended but not required for additional noise

filtering. See Typical Operating Circuit.

2

3

DXP1

Combined Remote-Diode Current Source and A/D Positive Input for Remote-
Diode Channel 1. DO NOT LEAVE DXP1 FLOATING; connect DXP1 to DXN if no
remote diode is used. Place a 2200pF capacitor between DXP1 and DXN for
noise filtering.

3

4

DXN

Combined Remote-Diode Current Sink and A/D Negative Input. DXN is internally
biased to one diode drop above ground.

4

5

DXP2

Combined Remote-Diode Current Source and A/D Positive Input for Remote-
Diode Channel 2. DO NOT LEAVE DXP2 FLOATING; connect DXP2 to DXN if no
remote diode is used. Place a 2200pF capacitor between DXP2 and DXN for
noise filtering.

5

10

OT1

Overtemperature Active-Low Output, Open Drain. OT1 is asserted low only when
the temperature is above the programmed OT1 threshold.

6

8

GND

Ground

7

9

SMBCLK

SMBus Serial-Clock Input

8

11

ALERT

SMBus Alert (Interrupt) Active-Low Output, Open-Drain. Asserts when
temperature exceeds user-set limits (high or low temperature) or when a remote
sensor opens. Stays asserted until acknowledged by either reading the status
register or by successfully responding to an alert response address. See the
ALERT Interrupts section.

9

12

SMBDATA

SMBus Serial-Data Input/Output, Open Drain

10

13

OT2

Overtemperature Active-Low Output, Open Drain. OT2 is asserted low only when
temperature is above the programmed OT2 threshold.

—

1, 16

N.C.

No Connect

—

6

ADD1

SMBus Slave Address Select Input (Table 10). ADD0 and ADD1 are sampled
upon power-up.

—

7

RESET

Reset Input. Drive RESET high to set all registers to their default values (POR
state). Pull RESET low for normal operation.

—

14

ADD0

SMBus Slave Address Select Input (Table 10). ADD0 and ADD1 are sampled
upon power-up.

—

15

STBY

Hardware Standby Input. Pull STBY low to put the device into standby mode.
All registers’ data are maintained.