General Description

The MAX6649 is a precise, two-channel digital temper-
ature sensor. It accurately measures the temperature of
its own die and a remote PN junction, and reports the
temperature in digital form using a 2-wire serial inter-
face. The remote PN junction is typically the emitter-
base junction of a common-collector PNP on a CPU,
FPGA, or ASIC.

The 2-wire serial interface accepts standard System
Management Bus (SMBus)™ write byte, read byte,
send byte, and receive byte commands to read the
temperature data and to program the alarm thresholds.
To enhance system reliability, the MAX6649 includes an
SMBus timeout. A fault queue prevents the ALERT and
OVERT outputs from setting until a fault has been
detected one, two, or three consecutive times
(programmable).

The MAX6649 provides two system alarms: ALERT and
OVERT. ALERT asserts when any of four temperature
conditions are violated: local overtemperature, remote
overtemperature, local undertemperature, or remote
undertemperature. OVERT asserts when the temperature
rises above the value in either of the two OVERT limit reg-
isters. The OVERT output can be used to activate a cool-
ing fan, or to trigger a system shutdown.

Measurements can be done autonomously, with the
conversion rate programmed by the user, or in a single-
shot mode. The adjustable conversion rate allows the
user to optimize supply current and temperature
update rate to match system needs.

Remote accuracy is ±1°C maximum error between +60°C
and +145°C with no calibration needed. The MAX6649
operates from -55°C to +125°C, and measures tempera-
tures between 0°C and +145°C. The MAX6649 is avail-
able in an 8-pin µMAX package.

Applications

Graphics Processors

Desktop Computers

Notebook Computers

Servers

Thin Clients

Workstations

Test and Measurement

Multichip Modules

Features

Dual Channel: Measures Remote and Local

Temperature

0.125°C Resolution
High Accuracy ±1°C (max) from +60°C to +145°C

(Remote), and ±2°C (max) from +60°C to +100°C
(Local)

Two Alarm Outputs: ALERT and OVERT
Programmable Under/Overtemperature Alarm

Temperature Thresholds

Programmable Conversion Rate
SMBus-Compatible Interface
SMBus Timeout

MAX6649

+145°C Precision SMBus-Compatible Remote/

Local Sensor with Overtemperature Alarms

________________________________________________________________ Maxim Integrated Products

1

Ordering Information

V

CC

DXP

DXN

10k

Ω EACH

CLOCK

TO FAN DRIVER OR
SYSTEM SHUTDOWN

3.3V

DATA

INTERRUPTED TO

µP

200

0.1

µF

SDA

SCLK

ALERT

GND

2200pF

µP

MAX6649

OVERT

Typical Operating Circuit

19-2540; Rev 0; 8/02

For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at
1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com.

PART

TEMP RANGE

PIN-
PACKAGE

MEASURED

TEMP RANGE

MAX6649MUA -55°C to +125°C 8 µMAX

0°C to +145°C