Rf12, Logic connections between power control bits – Rainbow Electronics RF12 User Manual
Page 15
Advertising

RF12
Logic connections between power control bits:
3. Frequency Setting Command
bit 15 14 13 12 11 10 9 8
7 6 5 4
3 2 1 0 POR
1
0
1
0
f11 f10
f9
f8
f7
f6
f5
f4
f3
f2
f1 f0 A680h
The 12-bit parameter F (bits f11 to f0) should be in the range of 96 and 3903. When F value sent is out of
range, the previous value is kept. The synthesizer band center frequency f
0
can be calculated as:
f
0
= 10 * C1 * (C2 + F/4000) [MHz]
The constants C1 and C2 are determined by the selected band as:
Band [MHz]
C1
C2
315
1
31
433
1
43
868
2
43
915
3
30
Tel: +86-755-86096587 Fax: +86-755-86096602 E-mail: [email protected] http://www.hoperf.com