Tables – Rainbow Electronics ADC12138 User Manual

Page 25

Advertising
background image

Tables

(Continued)

TABLE III ADC12130 and ADC12132 Multiplexer Addressing

Analog Channel Addressed

A D Input

Multiplexer

Mode

MUX

and Assignment

Polarity

Output

Address

with A DIN1 tied to MUXOUT1

Assignment

Channel

and A DIN2 tied to MUXOUT2

Assignment

DI0

DI1

CH0

CH1

COM

A DIN1

A DIN2

MUXOUT1

MUXOUT2

L

L

a

b

a

b

CH0

CH1

Differential

L

H

b

a

b

a

CH0

CH1

H

L

a

b

a

b

CH0

COM

Single-Ended

H

H

a

b

a

b

CH1

COM

Note

ADC12130 do not have A DIN1 A DIN2 MUXOUT1 and MUXOUT2 pins

TABLE IV Mode Programming

ADC12138

DI0

DI1

DI2

DI3

DI4

DI5

DI6

DI7

Mode Selected

(Current)

(next Conversion

DO Format

Cycle)

ADC12130

and

DI0

DI1

DI2

DI3

DI4

DI5

ADC12132

See Tables II or III

L

L

L

L

12 Bit Conversion

12 or 13 Bit MSB First

See Tables II or III

L

L

L

H

12 Bit Conversion

16 or 17 Bit MSB First

See Tables II or III

L

H

L

L

12 Bit Conversion

12 or 13 Bit LSB First

See Tables II or III

L

H

L

H

12 Bit Conversion

16 or 17 Bit LSB First

L

L

L

L

H

L

L

L

Auto Cal

No Change

L

L

L

L

H

L

L

H

Auto Zero

No Change

L

L

L

L

H

L

H

L

Power Up

No Change

L

L

L

L

H

L

H

H

Power Down

No Change

L

L

L

L

H

H

L

L

Read Status Register (LSB First)

No Change

L

L

L

L

H

H

L

H

Data Out without Sign

No Change

H

L

L

L

H

H

L

H

Data Out with Sign

No Change

L

L

L

L

H

H

H

L

Acquisition Time

6 CCLK Cycles

No Change

L

H

L

L

H

H

H

L

Acquisition Time

10 CCLK Cycles

No Change

H

L

L

L

H

H

H

L

Acquisition Time

18 CCLK Cycles

No Change

H

H

L

L

H

H

H

L

Acquisition Time

34 CCLK Cycles

No Change

L

L

L

L

H

H

H

H

User Mode

No Change

H

X

X

X

H

H

H

H

Test Mode

No Change

(CH1 – CH7 become Active Outputs)

Note

The A D powers up with no Auto Cal no Auto Zero 10 CCLK acquisition time 12-bit

a

sign conversion power up 12- or 13-bit MSB First and user mode

X

e

Don’t Care

TABLE V Conversion Read Data Only Mode Programming

CS

CONV

PD

Mode

L

L

L

See Table IV for Mode

L

H

L

Read Only (Previous DO Format) No Conversion

H

X

L

Idle

X

X

H

Power Down

X

e

Don’t Care

25

Advertising