Pin description – Rainbow Electronics MAX5068 User Manual

Page 8

Advertising
background image

MAX5068

High-Frequency, Current-Mode PWM Controller
with Accurate Programmable Oscillator

8

_______________________________________________________________________________________

Pin Description

PIN

MAX5068A
MAX5068B

MAX5068C

MAX5068E

MAX5068D

MAX5068F

NAME

FUNCTION

1

1

1

RT

Oscillator-Timing Resistor Connection. Connect a resistor from RT to AGND
to set the internal oscillator frequency.

2

2

SYNC

External-Clock Sync Input. Connect SYNC to AGND when not using an
external clock.

3

2

HYST

Programmable Hysteresis Input

3

3

SCOMP

Slope-Compensation Capacitor Input. Connect a capacitor to AGND to set
the slope compensation.

4

4

4

DT

Dead-Time Adjustment. Connect a resistor from DT to AGND to adjust NDRV
dead time. Connect to REG5 for maximum duty cycle.

5

5

5

UVLO/EN

Externally Programmable Undervoltage Lockout. UVLO/EN programs the
input start voltage. Drive UVLO/EN to AGND to disable the output.

6

6

6

FB

Error-Amplifier Inverting Input

7

7

7

COMP

Error-Amplifier Compensation Output

8

8

8

FLTINT

Fault-Integration Input. A capacitor connected to FLTINT charges with an
internal 60µA current source during repeated current-limit events. Switching
terminates when V

FLTINT

reaches 2.9V. An external resistor connected in

parallel discharges the capacitor. Switching resumes when V

FLTINT

drops to

1.6V.

9

9

9

CS

Current-Sense Resistor Connection

10, 12

10, 12

10, 12

AGND

Analog Ground. Connect to PGND through a ground plane.

11

11

11

PGND

Power Ground. Connect to AGND through a ground plane.

13

13

13

NDRV

G ate- D r i ver O utp ut. C onnect the N D RV outp ut to the g ate of the exter nal
N - channel FE T.

14

14

14

V

CC

9V Linear-Regulator Output. Decouple V

CC

with a minimum 1µF ceramic

capacitor to the AGND plane; also internally connected to the FET driver.

15

15

15

IN

Power-Supply Input. IN provides power for all internal circuitry. Decouple IN
with a minimum 0.1µF ceramic capacitor to AGND (see the Typical
Operating Circuit
).

16

16

16

REG5

5V Linear-Regulator Output. Decouple to AGND with a 0.1µF ceramic
capacitor.

EP

EP

EP

PAD

Exposed Pad. Connect to GND.

Advertising