Detailed Description

The MAX14527/MAX14528 overvoltage protection
devices feature a low R

ON

internal FET and protect low-

voltage systems against voltage faults up to +28V. If
the input voltage exceeds the overvoltage threshold,
the internal FET is turned off to prevent damage to the
protected components. The 15ms debounce time pre-
vents false turn-on of the internal FET during startup.

Device Operation

The MAX14527/MAX14528 have timing logic that
controls the turn-on of the internal FET. If V

IN

<

V

OVLO_THRESH

, the internal charge pump is enabled.

The charge-pump startup, after a 15ms debounce
delay, turns on the internal FET (see the

Functional

Diagram

). At any time, if V

IN

rises above V

OVLO_

THRESH

, OUT is disconnected from IN.

MAX14527/MAX14528

Adjustable Overvoltage Protector

with High Accuracy

_______________________________________________________________________________________

5

Pin Description

Functional Diagram

OUT

OUT

IN

IN

OVLO

GND

CHARGE

PUMP

LOGIC

CONTROL

SEL

V

BG

REFERENCE

+

-

TEMPERATURE

FAULTS

MAX14527
MAX14528

PIN

NAME

FUNCTION

1, 2

IN

Voltage Input. Bypass IN with a 1µF ceramic capacitor as close as possible to the device to obtain ±15kV
Human Body Model (HBM) ESD protection. Connect all the IN pins together for proper operation. IN is
protected to ±2kV HBM when IN is not bypassed with a capacitor to GND.

3

OVLO

External OVLO Adjustment. Connect OVLO to GND when using the internal threshold. Connect a resistor-
divider to OVLO to set a different OVLO threshold; this external resistor-divider is completely independent
from the internal threshold.

4, 5

I.C.

Internally Connected. Do not connect. Leave I.C. unconnected.

6

GND

Ground

7, 8

OUT

Output Voltage. Output of internal switch. Connect all the OUT outputs together for proper operation.

—

EP

Exposed Pad. Connect exposed pad to ground. For enhanced thermal dissipation, connect EP to a copper
area as large as possible. Do not use EP as a sole ground connection.