Electrical characteristics (continued) – Rainbow Electronics MAX6642 User Manual

Page 3

Advertising
background image

MAX6642

±1°C, SMBus-Compatible Remote/Local

Temperature Sensor with Overtemperature Alarm

_______________________________________________________________________________________

3

Note 1: All parameters tested at T

A

= +25°C. Specifications over temperature are guaranteed by design.

Note 2: Timing specifications guaranteed by design.
Note 3: The serial interface resets when SCLK is low for more than t

TIMEOUT

.

Note 4: A transition must internally provide at least a hold time to bridge the undefined region (300ns max) of SCLK’s falling edge.

ELECTRICAL CHARACTERISTICS (continued)

(V

CC

= +3.0V to +5.5V, T

A

= -40°C to +125°C, unless otherwise specified. Typical values are at V

CC

= +3.3V and T

A

= +25

°C.) (Note 1)

PARAMETER

SYMBOL

CONDITIONS

MIN

TYP

MAX

UNITS

SMBus-COMPATIBLE INTERFACE (SCLK and SDA)

Logic Input Low Voltage

V

IL

0.8

V

Logic Input High Voltage

V

IH

V

CC

= 3.0V

2.2

V

Input Leakage Current

I

LEAK

V

IN

= GND or 5.5V

-1

+1

µA

Output Low Sink Current

I

OL

V

OL

= 0.6V

6

mA

Input Capacitance

C

IN

5

pF

SMBus TIMING (Note 2)

Serial Clock Frequency

f

SCLK

(Note 3)

100

kHz

Bus Free Time Between STOP
and START Condition

t

BUF

4.7

µs

START Condition Setup Time

4.7

µs

Repeat START Condition Setup
Time

t

SU:STA

90% to 90%

50

ns

START Condition Hold Time

t

HD:STA

10% of SDA to 90% of SCLK

4

µs

STOP Condition Setup Time

t

SU:STO

90% of SCLK to 90% of SDA

4

µs

Clock Low Period

t

LOW

10% to 10%

4.7

µs

Clock High Period

t

HIGH

90% to 90%

4

µs

Data Setup Time

t

HD:DAT

(Note 4)

250

µs

Receive SCLK/SDA Rise Time

t

R

1

µs

Receive SCLK/SDA Fall Time

t

F

300

ns

Pulse Width of Spike Suppressed

t

SP

0

50

ns

SMBus Timeout

t

TIMEOUT

SDA low period for interface reset

20

28

40

ms