Rainbow Electronics MAX6512 User Manual

Page 2

Advertising
background image

MAX6511/MAX6512/MAX6513

Low-Cost, Remote SOT Temperature Switches

2

_______________________________________________________________________________________

ABSOLUTE MAXIMUM RATINGS

ELECTRICAL CHARACTERISTICS

(V

DD

= +3.0V to +5.5V, C

S

= 2200pF, T

A

= -40

°C to +85°C, T

REMOTE

= +45

°C to +125°C (Note 1), unless otherwise noted. Typical

values are at T

A

= +25

°C.) (Note 2)

Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.

Note 1: T

REMOTE

refers to the temperature of the remote-sensing junction. T

A

refers to the temperature of the MAX6511/MAX6512/

MAX6513 package.

Note 2: All parameters are 100% production tested at T

A

= +25

°C. Specifications over temperature limits are guaranteed by design.

Note 3: This parameter is guaranteed by design to ±3.5 sigma.

Supply Voltage (V

DD

) ...............................................-0.3V to +6V

DXP, DXN, HYST, TOVER (MAX6513),

TOVER (MAX6511/MAX6512) ................-0.3V to (V

DD

+ 0.3V)

TOVER (MAX6513), TOVER (MAX6511)

Output Current ....................................................-1mA/+50mA

DXN Input Current...................................................-1mA/+50mA
Current (all other pins)......................................................±20mA
Continuous Power Dissipation (T

A

= +70

°C)

6-Pin SOT23-6 (derate 9.1mW/°C above +70

°C) ........727mW

Operating Temperature Range ...........................-40

°C to +85°C

Storage Temperature Range .............................-65

°C to +150°C

Junction Temperature ......................................................+150

°C

Lead Temperature

Vapor Phase (60s) .......................................................+215

°C

Infrared (15s) ...............................................................+220

°C

PARAMETER

SYMBOL

CONDITIONS

MIN

TYP

MAX

UNITS

Supply Voltage Range

V

DD

3.0

5.5

V

Supply Current

I

DD

400

600

µA

T

A

= -5

°C to +55°C

-3.0

+3.0

Temperature Threshold
Accuracy (Note 3)

∆T

TH

T

A

= -40

°C to +85°C

-5.0

+5.0

°C

Power-Supply Sensitivity for
Temperature Trip Point

-0.6

°C/V

HYST = V

IL

5

Temperature Threshold
Hysteresis

T

HYST

HYST = V

IH

10

°C

Response Time

70

120

ms

Input Voltage High

V

IH

V

DD

-

0.2

V

Input Voltage Low

V

IL

0.2

V

Output Voltage High

V

OH

MAX6511/MAX6513, I

OUT

= 1mA

V

DD

- 0.2

V

Output Voltage Low

V

OL

I

OUT

= 1mA

0.2

V

Maximum DXP Source
Current

0.4V

≤ V

DXP

≤ 2V,

DXN = GND

270

µA

Minimum DXP Source
Current

0.4V

≤ V

DXP

≤ 2V,

DXN = GND

9

µA

Advertising