4

TH7813A/TH7814A

1990A–IMAGE–05/02

Timing Diagrams

The following diagram shows the general clocking scheme for the TH7813A and
TH7814A.

The line is composed as follows:

Postscan elements may be added in order to either increase the exposure time, or to
provide a voltage reference level.

Figure 3. Line Timing Diagram

The following diagram shows the timing for the transfer period:

Figure 4. Line Transfer Period

Φ

R clock may also be held in high state during line transfer period.

The following diagram shows the detailed timing for the pixel readout:

Synopsis

Number of Prescan

Pixels Per Output

Number of Useful
Pixels Per Output

Total Number of

Pixels Per Output

TH7813A

4

512

516

TH7814A

4

1024

1028

A

P

L1

L2

R

Line Period

Transfer Period

A

P

L1

L2

R

> 300 ns

> 10 ns

> 10 ns

first prescan pixel

(700 ns typ.)