Rainbow Electronics ADC0817 User Manual

Page 8

Advertising
background image

Typical Performance Characteristics

TRI-STATE Test Circuits and Timing Diagrams

Applications Information

OPERATION

1.0 RATIOMETRIC CONVERSION

The ADC0816, ADC0817 is designed as a complete Data
Acquisition System (DAS) for ratiometric conversion sys-
tems. In ratiometric systems, the physical variable being
measured is expressed as a percentage of full-scale which is
not necessarily related to an absolute standard. The voltage
input to the ADC0816 is expressed by the equation

(1)

V

IN

= Input voltage into the ADC0816

V

fs

= Full-scale voltage

V

Z

= Zero voltage

D

X

= Data point being measured

D

MAX

= Maximum data limit

D

MIN

= Minimum data limit

DS005277-18

FIGURE 6. Comparator I

IN

vs V

IN

(V

CC

=V

REF

=5V)

DS005277-19

FIGURE 7. Multiplexer R

ON

vs V

IN

(V

CC

=V

REF

=5V)

DS005277-9

DS005277-10

FIGURE 8.

www.national.com

8