Table 14. critical fault configuration – Rainbow Electronics MAX16071 User Manual

Page 24

Advertising
background image

12-Channel/8-Channel, Flash-Configurable System

Managers with Nonvolatile Fault Registers

MAX16070/MAX16071

24 _____________________________________________________________________________________

Table

14. Critical Fault Configuration

REGISTER

ADDRESS

FLASH

ADDRESS

BIT

RANGE

DESCRIPTION

6Dh

26Dh

[1:0]

Fault information to log
00 = Save failed line flags and ADC values in flash
01 = Save only failed line flags in flash
10 = Save only ADC values in flash
11 = Do not save anything

[2]

1 = Fault log triggered when EXTFAULT is pulled low externally

[7:3]

Not used

6Eh

26Eh

[0]

1 = Fault log triggered when MON1 is below its undervoltage threshold

[1]

1 = Fault log triggered when MON2 is below its undervoltage threshold

[2]

1 = Fault log triggered when MON3 is below its undervoltage threshold

[3]

1 = Fault log triggered when MON4 is below its undervoltage threshold

[4]

1 = Fault log triggered when MON5 is below its undervoltage threshold

[5]

1 = Fault log triggered when MON6 is below its undervoltage threshold

[6]

1 = Fault log triggered when MON7 is below its undervoltage threshold

[7]

1 = Fault log triggered when MON8 is below its undervoltage threshold

6Fh

26Fh

[0]

1 = Fault log triggered when MON9 is below its undervoltage threshold

[1]

1 = Fault log triggered when MON10 is below its undervoltage threshold

[2]

1 = Fault log triggered when MON11 is below its undervoltage threshold

[3]

1 = Fault log triggered when MON12 is below its undervoltage threshold

[4]

1 = Fault log triggered when MON1 is above its overvoltage threshold

[5]

1 = Fault log triggered when MON2 is above its overvoltage threshold

[6]

1 = Fault log triggered when MON3 is above its overvoltage threshold

[7]

1 = Fault log triggered when MON4 is above its overvoltage threshold

70h

270h

[0]

1 = Fault log triggered when MON5 is above its overvoltage threshold

[1]

1 = Fault log triggered when MON6 is above its overvoltage threshold

[2]

1 = Fault log triggered when MON7 is above its overvoltage threshold

[3]

1 = Fault log triggered when MON8 is above its overvoltage threshold

[4]

1 = Fault log triggered when MON9 is above its overvoltage threshold

[5]

1 = Fault log triggered when MON10 is above its overvoltage threshold

[6]

1 = Fault log triggered when MON11 is above its overvoltage threshold

[7]

1 = Fault log triggered when MON12 is above its overvoltage threshold

71h

271h

[0]

1 = Fault log triggered when MON1 is above/below the early threshold warning

[1]

1 = Fault log triggered when MON2 is above/below the early threshold warning

[2]

1 = Fault log triggered when MON3 is above/below the early threshold warning

[3]

1 = Fault log triggered when MON4 is above/below the early threshold warning

[4]

1 = Fault log triggered when MON5 is above/below the early threshold warning

[5]

1 = Fault log triggered when MON6 is above/below the early threshold warning

[6]

1 = Fault log triggered when MON7 is above/below the early threshold warning

[7]

1 = Fault log triggered when MON8 is above/below the early threshold warning