MAX8720
Dynamically Adjustable 6-Bit VID
Step-Down Controller
______________________________________________________________________________________
21
HIGH VID VOLTAGE
LOW VID VOLTAGE
PGOOD
SUS
SKIP
HIGH IMPEDANCE
HIGH IMPEDANCE
MODE
FORCED-PWM
FORCED-PWM
PWM MODE
PWM MODE
LOW VID
HIGH VID
HIGH VID
D0-D5
PWM MODE
V
OUT
SLEW RATE SET BY R
TIME
8x R
TIME
CLOCKS
8x R
TIME
CLOCKS
Figure 8. VID Transition in Forced-PWM Mode (
SKIP = High)
HIGH VID VOLTAGE
LOW VID VOLTAGE
PGOOD
SUS
SKIP
MODE
FORCED-PWM
FORCED-PWM
SKIP MODE
SKIP MODE
LOW VID
HIGH VID
HIGH VID
D0-D5
SKIP MODE
HIGH IMPEDANCE
HIGH IMPEDANCE
LOW T'HOLD ONLY
LOW THRESHOLD ONLY
V
OUT
SLEW RATE SET BY R
TIME
8x R
TIME
CLOCKS
8x R
TIME
CLOCKS
LOW T'HOLD ONLY