Preliminary w78c52d – Rainbow Electronics W78C52D User Manual
Page 12

Preliminary W78C52D
- 12 -
Data Read Cycle
PARAMETER
SYMBOL
MIN.
TYP.
MAX.
UNIT
NOTES
ALE Low to RD Low
T
DAR
3 T
CP
-
∆
-
3 T
CP+
∆
nS
1, 2
RD Low to Data Valid
T
DDA
-
-
4 T
CP
nS
1
Data Hold from RD High
T
DDH
0
-
2 T
CP
nS
Data Float from RD High
T
DDZ
0
-
2 T
CP
nS
RD Pulse Width
T
DRD
6 T
CP
-
∆
6 T
CP
-
nS
2
Notes:
1. Data memory access time is 8 T
CP
.
2. "
∆" (due to buffer driving delay and wire loading) is 20 nS.
Data Write Cycle
PARAMETER
SYMBOL
MIN.
TYP.
MAX.
UNIT
ALE Low to WR Low
T
DAW
3 T
CP
-
∆
-
3 T
CP
+
∆
nS
Data Valid to WR Low
T
DAD
1 T
CP
-
∆
-
-
nS
Data Hold from WR High
T
DWD
1 T
CP
-
∆
-
-
nS
WR Pulse Width
T
DWR
6 T
CP
-
∆
6 T
CP
-
nS
Note: "
∆" (due to buffer driving delay and wire loading) is 20 nS.
Port Access Cycle
PARAMETER
SYMBOL
MIN.
TYP.
MAX.
UNIT
Port Input Setup to ALE Low
T
PDS
1 T
CP
-
-
nS
Port Input Hold from ALE Low
T
PDH
0
-
-
nS
Port Output to ALE
T
PDA
1 T
CP
-
-
nS
Note: Ports are read during S5P2, and output data becomes available at the end of S6P2. The timing data are referenced to
ALE, since it provides a convenient reference.