TCM8230MD

(A)

Ver. 1.20

04/01/05

20/27


POWER ON SEQUENCE

DVDD

(1.5V)

IOVDD

(2.8V)

RESET

(from Outside)

SCL/SDA

VD

DOUT

100ms>x>=0ns

>0ns

> 1V

EXTCLK

(V

p-p

= 2.8V)

1st picture

2nd picture

Commands are available

>=100 cycles of EXTCLK

>=2000 cycles of EXTCLK

*

x

D_MASK=1

((VOUTPH + 3) - VRRPH) + 4
In default case: VOUTPH=35dec, VRRPH=38dec, ((35 + 3) - 38) + 4 = 4H

*

PVDD

(2.8V)

100ms>x>=0ns


TCM8230MD cannot output pictures after power on immediately. You should be sent some I

2

C commands

after power on as below.

Address=03h, Data=00h (Default Data=80h)


POWER OFF SEQUENCE

PVDD

(2.8V)

IOVDD

(2.8V)

EXTCLK

(V

p-p

= 2.8V)

100ms>x>=0ns

100ms>x>0ns

100ms>x>=0ns

DVDD

(1.5V)