Dc characteristics – 3.3v operation, Device timing: during operation, At6000(lv) series – Rainbow Electronics AT6010LV User Manual
Page 23

AT6000(LV) Series
23
Note:
1. Parameter based on characterization and simulation; it is not tested in production.
Device Timing: During Operation
DC Characteristics – 3.3V Operation
Symbol
Parameter
Conditions
Min
Max
Units
V
IH
High-level Input Voltage
Commercial
CMOS
70% V
CC
V
CC
V
TTL
2.0
V
CC
V
V
IL
Low-level Input Voltage
Commercial
CMOS
0
30% V
CC
V
TTL
0
0.8
V
V
OH
High-level Output Voltage
Commercial
I
OH
= -2 mA, V
CC
min
2.4
V
I
OH
= -6 mA, V
CC
min
2.0
V
V
OL
Low-level Output Voltage
Commercial
I
OL
= +2 mA, V
CC
min
0.4
V
I
OL
= +6 mA, V
CC
min
0.5
V
I
OZH
High-level Tristate
V
O
= V
CC
(max)
10
µA
Output Leakage Current
I
OZL
High-level Tristate
Without Pull-up, V
O
= V
SS
-10
µA
Output Leakage Current
With Pull-up, V
O
= V
SS
-500
µA
I
IH
High-level Input Current
V
IN
= V
CC
(max)
10
µA
I
IL
Low-level Input Current
Without Pull-up, V
IN
= V
SS
-10
µA
With Pull-up, V
IN
= V
SS
-500
µA
I
CC
Power Consumption
Without Internal Oscillator (Standby)
200
µA
C
IN
Input Capacitance
All Pins
10