Ata6839 [preliminary, Serial interface: timing – Rainbow Electronics ATA6839 User Manual
Page 12
Advertising

12
4955C–AUTO–09/07
ATA6839 [Preliminary]
8.
Serial Interface: Timing
Parameters
Test Conditions
Timing Chart No.
Symbol
Min. Typ. Max. Unit
DO enable after CS falling edge
C
DO
= 100 pF
1
t
ENDO
200
ns
DO disable after CS rising edge
C
DO
= 100 pF
2
t
DISDO
200
ns
DO fall time
C
DO
= 100 pF
-
t
DOf
100
ns
DO rise time
C
DO
= 100 pF
-
t
DOr
100
ns
DO valid time
C
DO
= 100 pF
10
t
DOVal
200
ns
CS setup time
4
t
CSSethl
225
ns
CS setup time
8
t
CSSetlh
225
ns
CS high time
Input register bit 14 (SCT) = high
9
t
CSh
17
ms
CS high time
Input register bit 14 (SCT) = low
9
t
CSh
2.1
ms
CLK high time
5
t
CLKh
225
ns
CLK low time
6
t
CLKl
225
ns
CLK period time
-
t
CLKp
500
ns
CLK setup time
7
t
CLKSethl
225
ns
CLK setup time
3
t
CLKSetlh
225
ns
DI setup time
11
t
DIset
40
ns
DI hold time
12
t
DIHold
40
ns
Advertising