Timing diagrams figure 9 – Rainbow Electronics DS1267 User Manual
Page 10
Advertising

DS1267
10 of 12
102199
4. Relative linearity is used to determine the change in voltage between successive tap positions. Device
test limits ±0.5 LSB.
5. Typical values are for T
A
= 25°C and nominal supply voltage.
6. -3 dB cutoff frequency characteristics for the DS1267 depend on potentiometer total resistance:
DS1267-010: 1 MHz; DS1267-050: 200 kHz; DS1267-100: 100 kHz.
7. C
OUT
is active regardless of the state of
RST
.
8. See Figure 9(a), (b), and (c).
9. See Figure 11.
10. Valid at 25
°C only.
TIMING DIAGRAMS Figure 9
(A) 3-WIRE SERIAL INTERFACE GENERAL OVERVIEW
(B) START OF COMMUNICATION TRANSACTION