DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode
13 of 26
Figure 11. Alarm Interrupt Threshold Register Formats
Current Accumulator Interrupt High Threshold
MSB-Address
80h LSB-Address
81h
S 2
14
2
13
2
12
2
11
2
10
2
9
2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
MSb
LSb
MSb
LSb
Units: 6.25
mVhrs
Current Accumulator Interrupt Low Threshold
MSB-Address
82h LSB-Address
83h
S 2
14
2
13
2
12
2
11
2
10
2
9
2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
MSb
LSb
MSb
LSb
Units: 6.25
mVhrs
Temperature Interrupt High Threshold
Address
84h
S 2
6
2
5
2
4
2
3
2
2
2
1
2
0
MSb
LSb
Units: 1.0°C
Temperature Interrupt Low Threshold
Address
85h
S 2
6
2
5
2
4
2
3
2
2
2
1
2
0
MSb
LSb
Units: 1.0°C