DS1621

11 of 16

102299

measurement will be completed and the DS1621 will remain idle until a Start Convert T is issued to
resume continuous operation.

DS1621 COMMAND SET Table 3

INSTRUCTION

DESCRIPTION

PROTOCOL

2-WIRE BUS DATA

AFTER ISSUING

PROTOCOL

NOTES

TEMPERATURE CONVERSION COMMANDS

Read Temperature

Read last converted temperature
value from temperature register.

AAh

<read 2 bytes data>

Read Counter

Reads value of count remaining
from counter.

A8h

<read data>

Read Slope

Reads value of the slope
accumulator.

A9h

<read data>

Start Convert T

Initiates temperature
conversion.

EEh

idle

1

Stop Convert T

Halts temperature conversion.

22h

idle

1

THERMOSTAT COMMANDS

Access TH

Reads or writes high
temperature limit value into TH
register.

A1h

<write data>

2

Access TL

Reads or writes low
temperature limit value into TL
register.

A2h

<write data>

2

Access Config

Reads or writes configuration
data to configuration register.

ACh

<write data>

2

NOTES:

1. In continuous conversion mode a Stop Convert T command will halt continuous conversion. To

restart the Start Convert T command must be issued. In one–shot mode a Start Convert T command
must be issued for every temperature reading desired.

2. Writing to the E

2

typically requires 10ms at room temperature. After issuing a write command, no

further writes should be requested for at least 10 ms.