Rainbow Electronics DS1621 User Manual
Page 11

DS1621
11 of 16
102299
measurement will be completed and the DS1621 will remain idle until a Start Convert T is issued to
resume continuous operation.
DS1621 COMMAND SET Table 3
INSTRUCTION
DESCRIPTION
PROTOCOL
2-WIRE BUS DATA
AFTER ISSUING
PROTOCOL
NOTES
TEMPERATURE CONVERSION COMMANDS
Read Temperature
Read last converted temperature
value from temperature register.
AAh
<read 2 bytes data>
Read Counter
Reads value of count remaining
from counter.
A8h
<read data>
Read Slope
Reads value of the slope
accumulator.
A9h
<read data>
Start Convert T
Initiates temperature
conversion.
EEh
idle
1
Stop Convert T
Halts temperature conversion.
22h
idle
1
THERMOSTAT COMMANDS
Access TH
Reads or writes high
temperature limit value into TH
register.
A1h
<write data>
2
Access TL
Reads or writes low
temperature limit value into TL
register.
A2h
<write data>
2
Access Config
Reads or writes configuration
data to configuration register.
ACh
<write data>
2
NOTES:
1. In continuous conversion mode a Stop Convert T command will halt continuous conversion. To
restart the Start Convert T command must be issued. In one–shot mode a Start Convert T command
must be issued for every temperature reading desired.
2. Writing to the E
2
typically requires 10ms at room temperature. After issuing a write command, no
further writes should be requested for at least 10 ms.