Modem Status Register

Register Name:

US_MS

This register provides the current state of the control lines from the modem (or peripheral device) to the CPU. In addition to
this current-state information, four bits of the Modem Status Register provide change information. These bits are set to
logic 1 whenever a control input from the modem changes state. They are reset to logic 0 whenever the CPU reads the
Modem Status Register.

•

DCTS: Delta Clear to Send

This bit is the Delta Clear to Send indicator. Bit 0 indicates that the NCTS input to the chip has changed state since the
last time it was read by the CPU.

•

DDSR: Delta Data Set Ready

This bit is the Delta Data Set Ready indicator. Bit 1 indicates that the NDSR input to the chip has changed state since
the last time it was read by the CPU.

•

TERI: Trailing Edge Ring Indicator

This bit is the Trailing Edge of Ring Indicator detector. Bit 2 indicates that the NRI input to the chip has changed from a
low to a high state.

•

DDCD: Delta Data Carrier Detect

This bit is the Delta Data Carrier Detect indicator. Bit 3 indicates that the NDCD input has changed state.

Note that whenever bit 0, 1, 2, or 3 is set to logic 1, a Modem Status Interrupt is generated. This is reflected in the
modem status register.

•

CTS: Clear to Send

This bit is the complement of the Clear to Send (NCTS) input. If bit 4 (loop) of the MCR is set to a 1, this bit is equiva-
lent to RTS in the MCR.

•

DSR: Data Set Ready

This bit is the complement of the Data Set Ready (NDSR) input. If bit 4 (loop) of the MCR is set to a 1, this bit is equiv-
alent to DTR in the MCR.

•

RI: Ring Indicator

This bit is the complement of the Ring Indicator (NRI) input. If bit 4 (loop) of the MCR is set to a 1, this bit is equivalent
to OUT1 in the MCR.

•

DCD: Data Carrier Detect

This bit is the complement of the Data Carrier Detect (NDCD) input. If bit 4 (loop) of the MCR is set to a 1, this bit is
equivalent to OUT2 in the MCR.

•

FCMS: Flow Control Status

This bit indicates the value of the FCM in the Modem Control Register.

31

30

29

28

27

26

25

24

–

–

–

–

–

–

–

–

23

22

21

20

19

18

17

16

–

–

–

–

–

–

–

–

15

14

13

12

11

10

9

8

–

–

–

–

–

–

–

FCMS

7

6

5

4

3

2

1

0

DCD

RI

DSR

CTS

DDCD

TERI

DDSR

DCTS