Rainbow Electronics DS1682 User Manual

Ds1682, Total elapsed time recorder with alarm, Features

Advertising
background image





1 of 15

041202

Note: Some revisions of this device may incorporate deviations from published specifications known as errata. Multiple
revisions of any device may be simultaneously available through various sales channels. For information about device
errata, click here:

http://dbserv.maxim-ic.com/errata.cfm

.







FEATURES

§ Records the total time that the event input has

been active and the number of events that
have occurred

§ 32-bit, nonvolatile, elapsed time counter

monitors event duration with quarter-second
resolution and provides 34 years of total time
accumulation

§ Programmable elapsed time ALARM output
§ Nonvolatile 17-bit event counter records the

total number of times an event has occurred

§ Calibrated, temperature-compensated RC

time base accurate to 2% typical

§ 10 bytes of EEPROM user memory
§ Write disable function to prevent the memory

from being changed or erased

§ 2-wire serial communication
§ Wide power-supply range (2.5V to 5.5V)
§ Useful in time-of-use warranty, calibration,

repair, and maintenance applications




PIN ASSIGNMENT









Package dimension information can be found at:

http://dbserv.maxim- ic.com/products.cfm

PIN DESCRIPTION

EVENT

- Event Input

ALARM

- Alarm Output

GND

- Ground

SDA

- Serial- Data I/O

SCL

- Serial-Clock Input

V

CC

- Voltage Supply

N/C

- No Connect

ORDERING INFORMATION

DS1682S 8-Pin SO (150mil) -40°C to +85°C


DESCRIPTION

The DS1682 is an integrated elapsed time recorder containing a factory-calibrated, temperature-
compensated RC time base that eliminates the need for an external crystal. Using EEPROM technology
to maintain data in the absence of power, the DS1682 requires no backup power source. The DS1682
detects and records the number of events on the EVENT pin and the total cumulative event time since the

DS1682 was last reset to 0. The ALARM pin alerts the user when the total time accumulated equals the

user-programmed alarm value. The polarity of the open-drain ALARM pin can be programmed to either
drive low or to become high impedance upon an alarm condition. The DS1682 is ideal for applications
that monitor the total amount of time that a device has been in operation and/or the number of uses since
inception of service, repair, or the last calibration.

SDA

1

SCL

EVENT

6

3

2

GND

V

CC

8

4

5

7

N/C

N/C

ALARM

Top View

DS1682S 8-Pin SO (150mil)

DS1682

DS1682

Total Elapsed Time Recorder

with Alarm

www.maxim-ic.com

Advertising