Ac electrical characteristics (0 °c to 70°c; v, 0v ±=10%) – Rainbow Electronics DS1673 User Manual
Page 15
Advertising

DS1673
15 of 18
AC ELECTRICAL CHARACTERISTICS
(0
°C to 70°C; V
CC
=3.0V
±=10%)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS NOTES
Data to Clock Setup
t
DC
150
ns
8
CLK to Data Hold
t
CDH
210
ns
8
CLK to Data Delay
t
CDD
600
ns
8, 9, 10
CLK to Low Time
t
CL
750
ns
8
CLK to High Time
t
CH
750
ns
8
CLK Frequency
t
CLK
0.667
MHz
8
CLK Rise and Fall
t
R
, t
F
1500
ns
CS to CLK Setup
t
CC
3
µs
8
CLK to CS Hold
t
CCH
180
ns
8
CS Inactive Time
t
CWH
3
µs
8
CS to I/O High-Z
t
CDZ
210
ns
8
V
CC
Slew Rate (2.7V to 2.3V)
t
F
300
µs
V
CC
Slew Rate (2.3V to 2.7V)
t
R
0
ns
V
CC
Detect to
RST
(V
CC
Falling)
t
RPD
200
ns
Reset Active Time
t
RST
250
ms
15
Pushbutton Debounce
PB
DB
250
ms
15
V
CC
Detect to
RST
(V
CC
Rising)
t
RPU
250
ms
15, 16
ST
Pulse Width
t
ST
40
ns
Chip Enable Propagation Delay to
External SRAM
t
CED
8
25
ns
Nominal Voltage to V
CC
Switchover
Fall Time
t
FB
300
µs
Advertising