Status register – Rainbow Electronics AT77C105A User Manual

Page 14

Advertising
background image

14

AT77C105A [Preliminary]

5419A–BIOM–01/05

Status Register

Register Name: Status (8 bits)

Access Type: Read Only

Function: State of AT77C105A

•

CLICK: Click detection

0: default

1: click detected

•

MOV: Movement detection

0: default

1: X or Y movement detected

•

TRANSIT: Not used, for testing only

•

SLICE: Not used, for testing only

•

READERR: Read error detection

0: default, no error

1: read error detected

Note:

To clear the interrupts, the status register is initialized after each reading from the host.

b7

b6

b5

b4

b3

b2

b1

b0

CLICK

MOV

TRANSIT

SLICE

READERR

–

–

–

0

0

0

0

0

0

0

0

Advertising