DS1384

16 of 17

TIMING DIAGRAM: INTERRUPT OUTPUTS PULSE MODE (SEE NOTES 8, 9)

NOTES:

1. All voltages are referenced to ground.

2. Typical values are at 25

°

C and nominal supplies.

3. Outputs are open.

4. Value for voltage and currents is from the V

CCI

input pin to the V

CCO

pin.

5. Write protection trip point occurs during power fail prior to switchover from V

CC

to V

BAT

.

6. Value for voltage and currents is from the V

BAT

input pin to the V

CCO

pin.

7. Data retention time depends on the size of battery selected and the amount of current demanded by

the static RAM in back-up mode. The battery capacity (mA

=hr) to achieve a T

DR

of 10 years is given

by the formula: C=(I

BAT1

+ I

RAM

) x 24 x 365 x 10, where I

RAM

is the standby current of the static

RAM at the battery voltage. For the DS1384 chip alone, a standard 48 mAh lithium cell battery will
provide greater than 10 years of data retention in the absence of power.

8. Applies to both interrupt pins when the alarms are set to pulse.

9. Interrupt output occurs within 100 ns of the alarm condition existing.

OUTPUT LOAD