Ac characteristics for the at22lv10l, Input test waveforms and measurement levels, Output test loads – Rainbow Electronics AT22LV10L User Manual
Page 5: Commercial, At22lv10(l)
Advertising
AT22LV10(L)
5
Input Test Waveforms and
Measurement Levels
Output Test Loads
Commercial
AC Characteristics for the AT22LV10L
Symbol
Parameter
AT22LV10L-25
Units
Min
Typ
Max
t
PD
Input or Feedback to Non-Registered Output
15
25
ns
t
EA
Input to Output Enable
15
25
ns
t
ER
Input to Output Disable
15
25
ns
t
CF
Clock to Feedback
0
5
9
ns
t
CO
Clock to Output
0
10
14
ns
t
SF
Feedback Setup Time
12
7
ns
t
S
Input Setup Time
17
15
ns
t
H
Hold Time
0
ns
t
P
Clock Period
12
ns
t
W
Clock Width
6
ns
F
MAX
External Feedback 1/(t
S
+ t
CO
)
32.2
MHz
Internal Feedback 1/(t
SF
+ t
CF
)
47.6
MHz
No Feedback 1/(t
P
)
83.3
MHz
t
AW
Asynchronous Reset Width
25
15
ns
t
AR
Asynchronous Reset Recovery Time
25
15
ns
t
AP
Asynchronous Reset to Registered Output Reset
18
28
ns
Advertising