Configuration register bit descriptions table 3 – Rainbow Electronics DS1821 User Manual

Page 7

Advertising
background image

DS1821

Page 7 of 17

CONFIGURATION REGISTER BIT DESCRIPTIONS Table 3

Bit Name

(User Access)

Functional Description

DONE — Temperature Conversion Done
(Read Only)

DONE = 0 — Temperature conversion is in progress.
DONE = 1 — Temperature conversion is complete.

NVB — Non-volatile Memory Busy
(Read Only)

NVB = 0 — Nonvolatile memory is not busy.
NVB = 1 — A write to EEPROM memory is in progress

THF* — Temperature High Flag
(Read/Write)

THF = 0 — The measured temperature has not exceeded the
value stored in the T

H

register.

THF = 1 — At some point in time the measured temperature has
been higher than the value stored in the T

H

register. THF will

remain a 1 until it is over-written with a 0 by the user.

TLF* — Temperature Low Flag
(Read/Write)

TLF = 0 — The measured temperature has not been lower than
the value stored in the T

L

register.

TLF = 1 — At some point in time the measured temperature has
been lower than the value stored in the T

L

register. TLF will

remain a 1 until it is over-written with a 0 by the user.

T/R

¯

* — Power-up Operating Mode

(Read/Write)

T/R

¯

= 0 — DS1821 powers up in 1- wire mode.

T/R

¯

= 1 — DS1821 powers up in thermostat mode.

POL* — Thermostat Output (DQ) Polarity
(Read/Write)

POL = 0 — Thermostat output (DQ) is active low.
POL = 1 — Thermostat output (DQ) is active high.

1SHOT* — Conversion Mode
(Read/Write)

1SHOT = 0 — Continuous conversion mode. The Start Convert
T [EEh] command initiates continuous temperature conversions,
which can be stopped with the Stop Convert T [22h] command.
1SHOT = 1 — One-shot mode. The Start Convert T [EEh]
command initiates a single temperature conversion after which
the DS1821 returns to a low-power standby state.

*

Stored in EEPROM