Tcr1, 4 in, Trai) – Rainbow Electronics DS26519 User Manual

Page 228

Advertising
background image

DS26519 16-Port T1/E1/J1 Transceiver

228 of 310

Register Name:

TCR1 (T1 Mode)

Register Description:

Transmit Control Register 1

Register Address:

181h + (200h x (n - 1)) + (2000h x [(n - 1) / 8]): where n = 1 to 16


Bit

# 7 6 5 4 3 2 1 0

Name TJC TFPT TCPT

TSSE

GB7S

TB8ZS

TAIS TRAI

Default

0 0 0 0 0 0 0 0

Note: See

TCR1

for E1 Mode.


Bit 7: Transmit Japanese CRC-6 Enable (TJC)

0 = Use ANSI/AT&T:ITU-T CRC-6 calculation (normal operation).
1 = Use Japanese standard JT–G704 CRC-6 calculation.

Bit 6: Transmit F-Bit Pass Through (TFPT)

0 = F bits sourced internally.
1 = F bits sampled at TSERn (

T1.TCR2

.7 TFDLS must be programmed to 0).

Bit 5: Transmit CRC Pass Through (TCPT)

0 = Source CRC-6 bits internally.
1 = CRC-6 bits sampled at TSERn during F-bit time.


Bit 4: Transmit Software Signaling Enable (TSSE). This function is enabled by TB7ZS (

T1.TCR2

.0).

0 = Do not source signaling data from the

TS1

–16 registers regardless of the

SSIE1

–4 registers. The

SSIE1

–4 registers still define which channels are to have B7 stuffing performed.

1 = Source signaling data as enabled by the

SSIE1

–4 registers.

Bit 3: Global Bit 7 Stuffing (GB7S). This function is enabled by TB7ZS (

T1.TCR2

.0).

0 = Allow the

SSIE1

–4 registers to determine which channels containing all zeros are to be bit 7 stuffed.

1 = Force bit 7 stuffing in all zero byte channels of that port, regardless of how the

SSIE1

–4 registers are

programmed.

Bit 2: Transmit B8ZS Enable (TB8ZS)

0 = B8ZS disabled.
1 = B8ZS enabled.

Bit 1: Transmit Alarm Indication Signal (TAIS)

0 = Transmit data normally.
1 = Transmit an unframed all-ones code at TTIPn and TRINGn.

Bit 0: Transmit Remote Alarm Indication (TRAI)

0 = Do not transmit remote alarm.
1 = Transmit remote alarm.