_______________________________________________________________________________________

ABSOLUTE MAXIMUM RATINGS

ELECTRICAL CHARACTERISTICS

(V

CC

= +3.3V, STBY = V

CC

, configuration byte = X0XXXX00, T

A

= 0°C to +125°C, unless otherwise noted.)

Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.

V

CC

to GND ..............................................................-0.3V to +6V

DXP_, ADD_, STBY to GND........................-0.3V to (V

CC

+ 0.3V)

DXN_ to GND ........................................................-0.3V to +0.8V
SMBCLK, SMBDATA, ALERT to GND ......................-0.3V to +6V
SMBDATA, ALERT Current .................................-1mA to +50mA
DXN_ Current......................................................................±1mA
Continuous Power Dissipation (T

A

= +70°C)

QSOP (derate 8.30mW/°C above +70°C) ....................667mW

Operating Temperature Range .........................-55°C to +125°C
Junction Temperature ......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C

DXP_ forced to 1.5V

Remote-Diode Source Current

Low level (POR state)

Configuration byte =
X0XXXX10, high level

Configuration byte =
X0XXXX01, high level

High level (POR state)

7

10

13

200

50

DXN_ Source Voltage

0.7

V

Hardware or software standby,
SMBCLK at 10kHz

SMBus static

T

A

= 0°C to +85°C

T

A

= +60°C to +100°C

Average measured over 4s; logic inputs forced
V

CC

or GND

Temperature Error, Local Diode
(Notes 1, 2)

-3.5

+3.5

°C

-2.5

+2.5

Including long-term drift

Temperature Error, Remote Diode
(Notes 2, 3)

-5

+5

°C

-3

+3

T

R

= -55°C to +125°C

T

R

= +60°C to +100°C

PARAMETER

MIN

TYP

MAX

UNITS

Undervoltage Lockout Hysteresis

50

mV

Undervoltage Lockout Threshold

2.60

2.8

2.95

V

Supply Voltage Range

3.0

5.5

V

Initial Temperature Error,
Local Diode (Note 2)

-3

+3

°C

Power-On Reset (POR) Threshold

1.3

1.8

2.3

V

POR Threshold Hysteresis

50

mV

3

10

Standby Supply Current

5

12

µA

Temperature Resolution (Note 1)

8

Bits

-2

+2

Average Operating Supply Current

400

700

µA

Conversion Time

260

320

380

ms

70

100

130

µA

Address Pin Bias Current

160

µA

CONDITIONS

V

CC

input, disables A/D conversion, rising edge

T

A

= 0°C to +125°C

V

CC

, falling edge

From stop bit to conversion complete (all channels)

Logic inputs
forced to V

CC

or GND

ADD0, ADD1; momentary upon power-on reset

Monotonicity guaranteed

T

A

= +60°C to +100°C

ADC AND POWER SUPPLY

Advertising