Functional Description

(Continued)

12.3 Configuration Register — Address 00h

Power on default

<

7:0

>

= 00001000 binary

Bit

Name

Read/

Write

Description

0

Start

Read/Write

A one enables startup of monitoring operations, a zero puts the part in standby mode.

Note: The outputs of Interrupt pins will not be cleared if the user writes a zero to this
location after an interrupt has occurred unlike “INT_Clear” bit.At start up, limit checking
functions and scanning begin. Note, all limits should be set in the Value RAM before
setting this bit HIGH.

1

INT Enable

Read/Write

A one enables the INT Interrupt output.

2

INT polarity
select

Read/Write

A one selects an active high open source output while a zero selects an active low
open drain output.

3

INT_Clear

Read/Write

A one disables the INT and RST_OUT/OS outputs without affecting the contents of
Interrupt Status Registers. The device will stop monitoring. It will resume upon clearing
of this bit.

4

RESET

Read/Write

A one outputs at least a 10 ms active low reset signal at RESET, if

<

7

>

= 1 and

<

6

>

= 0 in the Fan Divisor/RST_OUT/OS Register. This bit is cleared once the pulse

has gone inactive.

5

Chassis Clear

Read/Write

A one clears the CI (Chassis Intrusion) pin. This bit clears itself after the CI pins
cleared.

6

GPO

Read/Write

A one in this bit drives a one on GPO (General Purpose Output) pin.

7

INITIALIZATION

Read/Write

A one restores power on default value to the Configuration Register, Interrupt Status
Registers, Interrupt Mask Registers, Fan Divisor/RST_OUT/OSRegister, and the OS
Configuration/Temperature Resolution Register. This bit clears itself since the power
on default is zero.