3.0 Application Hints

(Continued)

7.

The ideal place to connect the LM84’s GND pin is as
close as possible to the Processors GND associated

with the sense diode. For the Pentium II this would be
pin A14.

Noise on the digital lines, overshoot greater than V

CC

and

undershoot less than GND, may prevent successful SMBus
communication with the LM84. SMBus no acknowledge is
the most common symptom, causing unnecessary traffic on
the bus. Although, the SMBus maximum frequency of com-

munication is rather low (400 kHz max) care still needs to be
taken to ensure proper termination within a system with
multiple parts on the bus and long printed circuit board
traces.

4.0 Typical Applications

DS100961-15

FIGURE 6. Recommended Diode Trace Layout

DS100961-17

Using a Diode Connected 2N3904 as a Remote Temperture Sensing Element