Ac electrical characteristics, Lm81 – Rainbow Electronics LM81 User Manual
Page 8

AC Electrical Characteristics
The following specifications apply for +2.8V
DC
≤
V
+
≤
+3.8V
DC
on SMBCLK and SMBData, unless otherwise specified. Bold-
face limits apply for T
A
= T
J
= T
MIN
to T
MAX
; all other limits T
A
= T
J
= 25˚C. (Note 15)
Symbol
Parameter
Conditions
Typical
Limits
Units
(Note 9)
(Note 10)
(Limits)
SERIAL BUS TIMING CHARACTERISTICS
t
1
SMBCLK (Clock) Period
2.5
µs (min)
t
rise
SMBCLK and SMBData Rise Time
1
µs (max)
t
fall
SMBCLK and SMBData Fall Time
300
ns (max)
t
2
Data In Setup Time to SMBCLK High
100
ns (min)
t
3
Data Out Stable After SMBCLK Low
0
ns (min)
t
4
SMBData Low Setup Time to SMBCLK Low
(start)
100
ns (min)
t
5
SMBData High Hold Time After SMBCLK
High (stop)
100
ns (min)
t
TIMEOUT
SMBData or SMBCLK low time required to
reset the Serial Bus Interface to the Idle
State
31
25
35
ms
ms (min)
ms (max)
C
L
Capacitive Load on SMBCLK and SMBData
400
pF (max)
DS100072-4
FIGURE 1. Serial Bus Timing Diagram
LM81
www.national.com
8