MAX1947

Low Input/Output Voltage

Step-Up DC-DC Converter with

RESET

_______________________________________________________________________________________

3

Note 2: Limits are 100% production tested at T

A

= +25°C. Limits over the operating temperature range are guaranteed by design.

Note 3: When BATT is greater than the output-voltage set point, the part is in track mode (see the Track Mode section).

ELECTRICAL CHARACTERISTICS (continued)

(V

BATT

= 1.5V, T

A

= -40°C to +85°C, unless otherwise noted. Typical values are at T

A

= +25°C.) (Note 2)

PARAMETER

CONDITIONS

MIN

TYP

MAX

UNITS

Startup to Normal-Mode Output
Transition Voltage

50mV hysteresis, rising edge

1.40

1.62

1.73

V

T

A

= 0°C to +85°C

600

800

1000

NFET Current Limit

T

A

= -40°C to +85°C

580

800

1000

mA

T

A

= 0°C to +85°C

15

75

150

PFET Turn-Off Current

T

A

= -40°C to +85°C

10

75

150

mA

MAX1947ETA18

0.3

0.6

MAX1947ETA25

0.22

0.44

MAX1947ETA30

0.17

0.34

Internal NFET
On-Resistance

I

LX

= 100mA

MAX1947ETA33

0.15

0.3

MAX1947ETA18

0.5

1.0

MAX1947ETA25

0.35

0.7

MAX1947ETA30

0.28

0.56

Internal PFET
On-Resistance

I

LX

= 100mA

MAX1947ETA33

0.25

0.5

T

A

= +25°C

0.1

1

LX Leakage Current

SHDN = GND, V

OUT

= 0V,

V

LX

= 3.6V

T

A

= +85°C

1

µA

SHUTDOWN MODE

Shutdown Supply Current

SHDN = GND

2

4

µA

V

IH

0.8 x

V

BATT

SHDN Input Voltage

V

IL

0.18 x
V

BATT

V

SHDN = OUT or GND, T

A

= +25

°

C

1

100

SHDN Input Bias Current

SHDN = OUT or GND, T

A

= +85

°

C

5

nA

OUT Discharge Resistance in
Shutdown

SHDN = GND

500

1000

RESET

OUTPUT

Reset OUT Voltage Trip Level

V

OUT

falling, 1% hysteresis

87

90

93

%

Minimum V

OUT

for Valid Reset

0.9

V

Reset Timeout

65

140

235

ms

I

SINK

= 200µA

0.3

RESET Output Voltage

I

SOURCE

= 200µA

0.8 x V

OUT

V

Advertising