Appendix A: Default Gateway Settings
Setting Default Value
Gateway Name User assigned
Password password field is blank from factory
DHCP Enabled from factory
IP Address DHCP will configure. If a DHCP
Server is not available, the unit will
default to 169.254.102.39
Net Mask 255.255.0.0
Default Gateway 169.254.1.1
MAC Address Fixed - see bottom label
Firmware Version (Vx.x.x)
Hardware Version (Vx.x.x)
Port 1
Serial port mode RS-485
Baud Rate 9600
Data bits 8
Parity None
Stop bits 1
Protocol TCP
Serial timeout 0 seconds
Inter-character timer 0 ms
TCP port 502
Max connection 1