B&B Electronics 855-12900--07 - Manual User Manual
Page 5

2
PCI Bracket
Low Profile Bracket
LED Indicators
Each McPC/PCI-Giga-MediaLinX includes two LEDs, located on the RJ-45 connector.
LED functions are as follows:
FX LNK/ACT
Glows green when a link is established on the fiber port; blinks
green when activity is detected on the fiber port.
TX LNK/ACT
Glows amber when a link is established on the copper port; blinks
amber when activity is detected on the copper port.
Specifications
Environmental
Operating Temperature
+32°F to +122°F (0°C to +50°C)
Storage Temperature
-4°F to +158°F (-20°C to +70°C)
Humidity:
5 - 95% (non-condensing)
Power Consumption (Typical)
Current Draw
0.7A @ 5 VDC
Input Specifications
Power Input: 5V