LLDP - Configuration
Mode:
Enables or Disables LLDP on the Switch. Default: Disabled
Transmit Interval:
Specifies the interval at which LLDP frames are transmitted. Default = 30 seconds.
Transmit Hold Multiplier:
Specifies a multiplier on the Transmit Interval when calculating a Time-to-Live value. Default = 4.
Re-Initialization Delay:
Specifies a minimum time an LLDP port will wait before re-initializing after setting the port to disable followed by
setting a port to Tx-Only or Tx/Rx. This prevents excessive Notifications if someone toggles between Disabled and
Enabled on LLDP Port settings. Default = 2 Seconds.
Notification Interval
Specifies the interval between successive Notifications generated by the switch. If a port sends out a notification and
another port tries to send out a notification, the notification will not be sent until the interval expires.
Default = 5 Seconds.