B&B Electronics VESR321_ML_SL - Manual User Manual
Page 14

Setup and Connections
www.bb-elec.com
www.bb-europe.com
10
The Vlinx Manager Discovery window appears
.
Figure 11. Vlinx Manager Discovery Window
2. Configure your serial server as required.
Note: For more information on configuration options refer to Section 4: Description of Serial
Server Properties.
Configuring with the Web Interface
VESR321 family serial servers can be configured over the network using a standard web browser
such as Internet Explorer or Firefox.
To open the web configuration interface:
1. On a PC connected to the network, open a browser.
2.
In the browser’s address bar, type the IP address of the serial server.
Note: Your serial server comes from the factory pre-configured to receive an IP address from a
DHCP Server. If DHCP assignment is not available it will default to 169.254.102.39
The web interface Login page appears.