UL Installation Information
Underwriters Laboratories Conditions of Acceptability –
When installed in the end-use equipment, consideration
should be given to the following:
1. The wiring terminals are suitable for factory wiring only.
2. This device is to be mounted in a suitable enclosure
in the end-product.
3. This device is suitable for operation at a maximum surrounding
air temperature as described in the documentation.
4. These devices are intended for use in a pollution
degree 2 environment.
• Input Voltage: 10 – 30 VDC
• Input Power: 0.5 Watts
• Wire Range: 12 – 24 AWG
• Tightening Torque: 4 kgf-cm
• Temperature rating of field installed conductors is 105° C
minimum, sized for 60° C ampacity
• Use copper wire only
• Maximum surrounding ambient air temperature 80° C
Optically Isolated
RS-232 to RS-422/485 Converter
485LDRC9