B&B Electronics CTA4100A_D - Manual User Manual
Page 8

CTA USER MANUAL
2007-05-09 - 8 -
© DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
Counter
Switch
Function
OFF
ON
1 DIP
switch
Disabled Enabled
2 Counting
mode Counting
up
Counting
down
3
4
Output mode
See the table on
the right
5 Counting
speed
30cps 10Kcps
6 Reserved
-
-
7 Input
signal
NPN PNP
8
Width of reset signal 20ms 1ms
Switch 3
Switch 4 Output mode
OFF OFF
F
ON OFF N
OFF ON
C
ON ON R
Tachometer
Switch
Function
OFF
ON
1 DIP
switch
Disabled Enabled
2 Reserved
-
-
3
4
Output mode
See the table on
the right
5 Counting
speed
30Hz 10KHz
6 Reserved
-
-
7 Input
signal
NPN PNP
8
Width of reset signal 20ms 1ms
Switch 3
Switch 4 Output mode
OFF OFF Lo-Lo
ON OFF Lo-Hi
OFF ON Hi-Lo
ON ON Hi-Hi
※
When Switch 1 is enabled (ON), the parameters can only be set up by Switch 1 ~ Switch 8 and cannot
be modified in the system. If the parameters have to be set in the system, please disable Switch 1
(OFF).