B&B Electronics CTA4100A_D - Datasheet User Manual

Digital timers/counters/tachometers, Relays and timers, General specifications wiring

Advertising
background image

Relays and Timers

No Games, No Gimmicks...

...Just Great Products at Great Prices!!!

www.factorymation.com

To order call1.800.972.0436 or visit factorymation.com

Digital Timers/Counters/Tachometers

3-in-1 Timer/ Counter/Tachometer

• Operates as timer, counter, or tachometer
• 2 line x 6 digit LCD display
• Dry contact or NPN/PNP input selectable
• Dual outputs available in two configurations
• +12VDC (100mA) output for encoder or sensor power
• 12 function timer includes:

On Delay, Off Delay, Signal On,

Power On Delay, Repeat Cycle, Cumulative, On/Off Cycle

• Counting modes include:

1-stage, 2-stage, batch, dual counting,

and totalizing

• Maximum count speed 5K cps
• Timer + Counter mixed mode function
• Tachometer measures frequency
• “Reset” and “Lock” keys
• External Start and Reset capability

Input Voltage

100–240VAC, 50/60Hz

24VDC ±10%

Input voltage range

85% to 110%, rated voltage

21.6 to 26.4VDC

Power consumption

Less than 10VA

Less than 5W

External power supply

12VDC ±10%, 100mA

Display

Double-line, 6-digit LCD display

Input signal

Non-voltage input (NPN):

ON impedance 1K ohm max.

ON residual voltage: 2V max.

Voltage input (PNP):

High level: 4.5 to 30VDC,

Low level: 0 to 2VDC

Output 1

(Transistor and Relay)

Relay:

SPST max.250VAC,

5A (resistance load)

Transistor:

NPN open collector.

When 100mA/30VDC,

residual voltage = 1.5VDC max.

Output 2

(Transistor or Relay)

Relay:

SPDT max.250VAC,

5A (resistance load)

Transistor:

NPN open collector.

When 100mA/30VDC,

residual voltage = 1.5VDC max.

Dielectric strength

2000VAC 50/60 Hz for 1 minute

Vibration resistance

Without damage: 10–55Hz, amplitude = 0.75mm, 3 axes

for 2 hours

Shock resistance

Without damage: drop 4 times, 300m/s2,

3 edges, 6 surfaces and 1 corner

Ambient temperature

0°C to +50°C

Storage temperature

-20°C to +65°C

Altitude

2000m or less

Ambient humidity

35% to 85% RH (non-condensing)

Pollution degree

Degree 2

Environmental

Protection

IP65 on front panel

Part Number Input

Voltage

Description

CTA4000A

100–240VAC

Output 1: Transistor/Relay comb.

Output 2: Transistor

CTA4000D

24VDC

Output 1: Transistor/Relay comb.

Output 2: Transistor

CTA4100A

100–240VAC

Output 1: Transistor/Relay comb.

Output 2: Relay

CTA4100D

24VDC

Output 1: Transistor/Relay comb.

Output 2: Relay

General Specifications

Wiring

6

8

7

9

10

RST2/

START

RST1

+12V

COM

11

2

1

3

1

14

15

0V

CP1

CP2/

GATE

NO

1

4

3

2

5

AC 100~240V

50/60 Hz 10VA Max.

~

C

E

OUT1

OUT2

CTA4000A

6

8

7

9

10

RST2/

START

RST1

+12V

COM

11

2

1

3

1

14

15

0V

CP1

CP2/

GATE

NO

1

4

3

2

5

AC 100~240V

50/60 Hz 10VA Max.

~

C

E

OUT1

OUT2

CTA4100A

6

8

7

9

10

RST2/

START

RST1

+12V

COM

11

2

1

3

1

14

15

0V

CP1

CP2/

GATE

NO

1

4

3

2

5

C

E

OUT1

OUT2

CTA4000D

6

8

7

9

10

RST2/

START

RST1

+12V

COM

11

2

1

3

1

14

15

0V

CP1

CP2/

GATE

NO

1

4

3

2

5

C

E

OUT1

OUT2

CTA4100D

GND

24VDC

GND

24VDC

Dimensions

Overall

Cutout

A

B

C

A

B

48.0 mm

(1.89”)

48.0 mm

(1.89”)

85.8 mm

(3.38”)

44.8 mm

(1.76”)

44.8 mm

(1.76”)

B

A

C

1/16

DIN

Advertising