Dip switch setting, Verifying installation, Pinouts – B&B Electronics USO9ML2-LS - Quick Start Guide User Manual

Page 2

Advertising
background image

P#8506R2 ULINX 1&2 PORT_0712qsg

5

Dip Switch Setting

TDA(-)

TDB(-)

RDA(-)

RDB(-)

GND

USB

TO PC

RS-485

RS-232 and TTL Pinout (DB9 Male DTE)

PIN

Signal Nam e

RS-232

Signals

TTL

Signals

1

DCD (Data Carrier Detect)

Input

Not Used

2

RD (Receive Data)

Input

Input

3

TD (Transmit Data)

Output

Output

4

DTR (DTE Ready)

Output

Not Used

5

SG (Signal Ground)

Ground

Ground

6

DSR (DCE Ready)

Input

Not Used

7

RTS (Request to Send)

Output

Output

8

CTS (Clear to Send)

Input

Input

9

RI (Ring Indicator)

Input

Not Used





















































NOTE: To remove drivers from a PC, there is an Uninstall
reference document on the CD ROM.

1. To verify the installation went correctly open the Windows

Device Manager

Scroll down to Ports,

Expand the ports by clicking on the plus sign (+), this
shows if the ports now exist on the PC.

If there are no exclamation points or other indicators of
a problem the ports should be installed correctly and
ready for use.

2. Verifying with a loopback test.

If the device is RS-232, loopback pins 2 and 3. If the
device is RS-422 or RS-485, loopback the TDA(-) to
RDA(-) and TDB(+) to RDB(+). Use the pin-out charts
for the location of each pin or terminal.

Using Hyper Terminal or similar program, connect to
the appropriate COM port. Set the desired baud rate.
Ensure Hyper Terminal local echo is OFF. (Note:
Hyper Terminal is not provided with Vista or 2003
Server)

Transmit data. If the same character string is returned,
the test is good.

4

Verifying Installation

Dip Sw itch Settings

Sw itch

Off (left)

On (right)

1

RS-422

RS-485

2

ECHO ON

ECHO OFF

3

4-Wire

2-Wire

4

4-WIre

2-Wire

6

Pinouts

RS485 Pinout (Term inal Blocks)

Term inal

Position RS-485, 4 Wire

RS-485, 2 Wire

A

Transmit TDA (-) Output

Data A (-) Input / Output

B

Transmit TDB (+) Output

Data B (+) Input / Output

C

Receive RDA (-) Input

Data A (-) Input / Output

D

Recieve RDB (+) Input

Data B (+) Input / Output

E

Ground

Ground

Note: For models with selectable RS-422/485 configurations

Dip switches allow the module to be configured for two-wire or
four-wire, RS-422 or RS-485 modes. In two-wire mode the TDA (-)
and RDA (-) are tied together and so are TDB (+) and RDB (+),
making multi-dropping this converter into an existing network easy.

RS-232

RS-485 Pinout (DB9 Fem ale)

Pin

RS-485, 4 Wire

RS-485, 2 Wire

1

Not Used

Not Used

2

Receive RDA (-) Input

Data A (-) Input / Output

3

Transmit TDB (+) Output

Data B (+) Input / Output

4

Ground

Ground

5

Not Used

Not Used

6

Ground

Ground

7

Receive RDB (+) Input

Data B (+) Input / Output

8

Transmit TDA (-) Output

Data A (-) Input / Output

9

Not Used

Not Used

DB9 Male

DB9 Female

Advertising