Duro-Last Stack Flashing User Manual

Duro-last, Stack flashing, Data sheet

Advertising
background image

Duro-Last: The Proven Performer®

"Duro-Last" and "The World's Best Roof" are registered marks owned by Duro-Last , Inc.

www.duro-last.com

800-248-0280

DATA SHEET

2009

11

DURO-LAST

®

STACK FLASHING

Description:
Duro-Last® Stack Flashings are required for all round
penetrations encountered on a roofing project. The

stack flashings are made with Duro-Last specially
formulated roofing membrane. The combination of

reinforced membrane and prefabrication ensures a
long lasting, watertight flashing.

Stack flashings are available in white, tan, gray and
dark gray colors. They can also be ordered with

Designer Series membrane (slate gray Shingle-Ply,

sandstone Shingle-Ply or Rock-Ply) bases and solid
color risers. They are available in diameters of 1 in.
(25 mm), 1.5 in. (38 mm) and in 1 in. increments

between 2 and 15 in. (51-381 mm). Stack Flashings

with diameters of 16 in. (406 mm) and larger are

available in 2 in. (51 mm) increments.

The flashings are manufactured oversized to account
for the thickness a schedule 40 pipe wall by the
following amounts:

1.5 - 4 in. (38 - 101 mm) diameter stack flashings

are 5/8 in. (15 mm) oversized.

All other sizes are 3/8 in. (9 mm) oversized.

Installation:

1. The roof membrane installed around the

penetration must be fastened prior to installing the

stack flashing. Use the same fastener spacing that

was used to install the roof membrane but do not

exceed 18 in. (457 mm) on center. At least one
fastener must be installed. On reroofing
applications, remove the existing flashings to
ensure a watertight fit.

2. Place the stack flashing around the penetration.

Heat weld the vertical seam if the stack was

ordered “open”.

3. Weld the stack flashing skirt to the roof membrane.

Care should be taken to smooth out the skirt so
that it is wrinkle-free.

4. Apply a bead of Duro-Caulk Plus® to the

penetration 1/4 in. (6 mm) below the top of the

stack flashing.

5. Install a stainless steel band approximately 1/4 in.

(6 mm) from the top of the stack flashing. Tighten

the band to draw the flashing firmly into the sealant.
Apply a bead of the Duro-Caulk Plus® around the
top of the flashing to assure a positive seal.

6. See details 4070, 4080 and 4081 for information on

installing stack flashings to specific types of round
penetrations.

Note:

Stack flashings and bands shall be furnished by
Duro-Last, Inc.

Field fabrication of flashings for round penetrations
is not allowed.

Stack flashings with diameters 16 in. (406 mm) and
larger are available "open" only.

An "open" stack flashing requires a heat weld

(hot-air) to close the flashing. The extra material
necessary for this weld is included as part of the

stack flashing.

CLOSED

OPEN

Stack Flashing Dimensions

Diameter

Available

Height

Base/Skirt

Closed Open

1 in.

(25 mm)

Yes

No

8 in.

(203 mm)

18 x 18 in. Base

(457 x 457 mm)

1.5 in.

(38 mm)

Yes

Yes

8 in.

(203 mm)

18 x 18 in. Base

(457 x 457 mm)

2 - 8 in.

(51 - 203 mm)

Yes

Yes

8 in.

(203 mm)

18 x 18 in. Base

(457 x 457 mm)

9 - 15 in.

(228 - 381 mm)

Yes

Yes

8 in.

(203 mm)

24 x 24 in. Base

(609 x 609 mm)

16 in.

(406 mm)

and Larger

No

Yes

8 in.

(203 mm)

6 or 12 in. Skirt

(152 or 305 mm)